Article No. 307420
Opaque water-based industrial intermediate coating and finishing coat for spraying
Product specifications
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- For use on interior and exterior wood
- Soft and hard woods
- Dimensionally stable wood building elements: e.g. windows and doors
- Intermediate and finishing coats
- Preferably as a single coat
Properties
- High degree of process reliability for industrial use
- Good hiding power
- Good flow properties
- Supports sealing when used with suitable primer and intermediate coatings
- Good block resistance
- Good resistance to yellowing and chalking
- Dirt-resistant
- Special combination of binding agents creates an extremely hard-wearing surface
- Good hail resistance
-
Preparation
-
Substrate requirements
The substrate must be clean, dry, free of dust, grease and loose substances, and prepared in the correct manner.
Dimensionally stable wood building elements: wood moisture content 11-15%
-
Preparations
If necessary, impregnate non-resistant woods with a wood preservative* (*Use biocides safely. Always read the label and product information before use).
Pre-treat using a suitable primer & intermediate coat and carry out intermediate sanding if necessary.
If necessary, protect parapet joints with Induline V-Joint Protection or Induline AF-920.
-
-
Application
-
The values given are based on undiluted material. The best spraying pattern is achieved if the material has a temperature of 15-20 °C.
Ensure good ventilation.
Check colour and compatibility with the substrate by applying a trial coat.
Airless spraying: nozzle size: 0.28-0.33 mm; material pressure: 90-120 bar.
Air-mix spraying: nozzle size: 0.28-0.33 mm; material pressure: 70-90 bar, atomiser air pressure 1-2 bar.
Seal opened containers well and use contents as soon as possible.
-
Application instructions
-
Check colour, adhesion and compatibility with the substrate by setting up a trial area.
Before coating technically modified woods and wood-based materials, apply the product to a trial surface and conduct a suitability test on the desired area of use.
Prior to full application, please apply a test coat to a sample area under practical conditions using the desired system, then test or examine the surface properties.
Do not use in direct sunlight or at temperatures below +15 °C or above +30 °C.
Ensure good ventilation.
Recycling is possible via the standard channels. Liaise with Remmers Technical Service if coatings have been mixed.
To prevent coloured substances contained in the wood from showing through, use a suitable primer and intermediate coating with a sealing effect on white or light-coloured surfaces.
With water based coating systems, there is always a residual risk that substances contained in the wood will cause discolouration.
To avoid thicker coats, e.g. in the case of full-tone colours, pretreat with translucent rather than white primer. Then add the coloured topcoat as the intermediate coat.
The specifications of VFF Code of Practice HO.03 must be observed with regard to the permitted dry layer thicknesses.
The system finder on our website www.remmers.com contains coating recommendations for specific wood types to be used when treating windows and exterior doors.
-
Drying
Dust dry: after approx. 1 hour
Ready for sanding and next coat: after approx. 4 hours
(practice values at 23 °C and 50% RH and a wet film thickness of 150 - 175 µm)
After forced drying, ready for sanding and next coat: 20 minutes flash-off time (at approx. 20 °C and 65-75% RH) / 75 minutes drying time (approx. 38 °C, 1 m/s air circulation) / 20 minutes cooling time -
Thinning
Dilute with water if necessary (max. 5%)
-
Working tools / cleaning
-
Airless/airmix spraying equipment, electrostatic equipment, dynflow equipment
-
Clean tools with water or Aqua RK-898 Cleaning Concentrate immediately after use.
Ensure that any residue from cleaning is disposed of correctly.
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 15 months.
-
Usage
-
Two spray applications:
150 - 175 ml/m² each (plus spraying loss)
(corresponds to wet film thickness of 150 - 175 μm, dry film thickness of 55 - 65 μm)
One spray application:
300 - 325 ml/m² (plus spraying loss)
(corresponds to wet film thickness of 300 - 325 μm, dry film thickness of 110 - 120 μm)
Values may differ depending on the colour.
-
General information
-
DIN EN 71-3 "Migration of certain elements":
This product complies with the limits for the migration of heavy metals to children's toys according to DIN EN 71-3 and thus fulfils one of several further requirements for the safety of children's toys according to the EU "Toy Directive" (2009/48/EC).Sealing:
Sealing compounds must be compatible with the coating and may only be applied once the coating has dried thoroughly.
Only use sealing profiles that are free of plasticisers.
Where the coating substances used are rich in colour, colour rub-off may occur, e.g. during cleaning. These effects are temporary and sporadic and do not impact the quality of the product in any way. Please see the technical information contained in TI 5.12 "Paint chalking".
Production of a brushing quality:
This product can be used with Induline Mix & Go to produce an easy-to-apply lacquer for reconditioning and repair work.
Care and maintenance:
Wood is subjected to great climatic and environmental stresses when outdoors. The coat is susceptible to the processes of natural ageing, wear and decomposition. Decomposition takes place at different speeds, depending on the stress (weak, average, strong) placed on the wood building element. Weathering stages may vary according to the part or element affected. To give wood the longest and best possible protection it is advisable to examine surfaces every year. Any damage found should be addressed immediately after cleaning.
For cleaning and care, we recommend the care set for windows (2745) and doors (2746).
Use Aqua AG-26 Universal Primer and Aqua DL-65 Opaque Top PU or Aqua VL-66/sm Venti-Coat 3in1 for reconditioning coats.
Observe current standards and guidelines for coating wood building elements outdoors (Codes of Practice issued by the German Association of Window and Facade Manufacturers (VFF), Code of Practice No. 18 issued by the German Federal Committee for Paint and the Protection of Material Assets (BFS), guidelines issued by the German Lacquer and Printing Ink Association (VdL) and ift guidelines issued by the Institut für Fenstertechnik).
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-