Article No. 2752860
Plasticiser-free, alkoxy-cross-linking silicone sealant
Product specifications
100% (DIN EN ISO 8339) 0.5 N/mm²
(DIN EN ISO 8339) > 200%
(DIN EN ISO 7389) > 90%
(DIN EN ISO 10563) approx. < 3%
(DIN EN 15651-1) ± 20%
The stated values represent typical product characteristics and are not to be construed as binding product specifications.
Field of application
- Natural stone
- Joints subjected to especially high mechanical and chemical stresses
- Areas that are permanently underwater
- Food industry
- Medical treatment rooms
Properties
- No discolouration on natural stone
- Highly resistant to mechanical and chemical stresses
- Highly elastic
-
Preparation
-
Substrate requirements
The sides of the joints must be dry to slightly damp, clean, free from grease and capable of bearing a load, and metals must be sound.
Adhesive primer
Natural stone - Silicone Primer P
Joints subjected to high stresses - Silicone Primer P
Underwater areas:
Dry joint edges - Underwater Primer
Slightly damp joining edges - Epoxy MT 100
-
-
Application
-
Application requirements
Temperature of the material, air and substrate: from min. +5 °C to max. +35 °C
-
Cut off tip at an angle to match the joint width.
Apply the material to the joint edges with sufficient pressure.
Pull off using a smoothing agent and a suitable tool.
-
Application instructions
-
Take appropriate measures to protect adjacent building elements and materials that should not come into contact with the product.
Joint dimensions depend on the loading stresses, the building material properties, and the permissible total deformation of the sealant.
The applicable regulations and legal requirements must be observed.
Can be removed with V 101 while wet.
Once the material has cured, remove contamination mechanically and clean using Silicone Remover.
-
-
Working tools / cleaning
-
Manual or compressed air gun, smoothing tool, adhesive tape
-
Manual or compressed air gun, smoothing tool, adhesive tape
Clean with V 101 while wet.
-
Storage / shelf life
-
If stored unopened in its original container in a cool, dry place and protected against frost, the product will keep for at least 12 months.
-
Usage
-
100 ml/running metre for a 1 cm² joint cross-section
-
Apply to a large enough trial area to determine the precise amount required.
-
General information
-
Current regulations and legal requirements must be taken into account and deviations from these must be agreed separately.
The relevant test certificates must be observed when planning and carrying out work.
Always set up a trial area/trial areas first.
-
-
Disposal instructions
-
Larger quantities of leftover product should be disposed of in the original containers in accordance with the applicable regulations. Completely empty, clean containers should be recycled. Do not dispose of together with household waste. Do not allow to enter the sewage system. Do not empty into drains.
-
-
Safety / regulations
-
For further information on the safety aspects of transporting, storing and handling the product and on disposal and environmental matters, please see the current Safety Data Sheet.
-